摘要:<span style="font-family:宋體;font-size:small;"> </span> <p style="margin:0cm 0cm 0pt;"> <span style="font-family:宋體;mso-ascii-font-family:"mso-hansi-font-family:";"><span style="font-size:small;">為什麼醫院要采用不鏽鋼管輸送氧氣</span></span> </p> <span style="font-family:宋體;font-size:small;"> </span> <p style="margin:0cm 0cm 0pt;"> <span style="font-size:small;"><span style="font-family:"Times New Roman";"><span lang="EN-US">  </span></span><span style="font-family:宋體;mso-ascii-font-family:"mso-hansi-font-family:";">氧是自然界分布*廣泛的元素之一。它以遊離狀態和化合狀態存在於自然界中,空氣中遊離狀態的氧達</span><span style="font-family:"Times New Roman";"><span lang="EN-US">20.93%</span></span><span style="font-family:宋體;mso-ascii-font-family:"mso-hansi-font-family:";">。化合狀態的氧存在於水、礦物、植物和動物等物體中。在常溫及大氣壓力下,氧為無色、無味、無臭的透明氣體,比空氣略重。氧的化學性質非常活潑,是強烈的氧化劑和阻燃劑。在一般情況下,他除了與金、銀、鉑及惰性氣體不發生化合外,與其他物質都能化合生成氧化物,氧與其他物質化合的過程即為氧化反應。氧與可燃氣體如氫、乙炔、甲烷等按一定比例混合後很容易爆炸。氧經壓縮後在輸送過程中如有油脂、氧化鐵銷及其他易燃物質存在時,隨著氣流與管壁的摩擦撞擊產生大量摩擦熱,可能會導致不鏽鋼管和設備的介質燃燒或爆炸。壓縮氧氣混雜有水分,會使不鏽鋼氧氣管道產生凝結水,純度越高的氧氣對不鏽鋼管的腐蝕越嚴重。針對氧氣管道的這些特點,在管道安裝及維修中要合理選材,並有相應的技術措施。</span></span> </p> <span style="font-family:宋體;font-size:small;"> </span> <p style="margin:0cm 0cm 0pt;"> <span style="font-size:small;"><span style="font-family:"Times New Roman";"><span lang="EN-US">  </span></span><span style="font-family:宋體;mso-ascii-font-family:"mso-hansi-font-family:";">工業生產中使用的氧氣,一種是由製氧直接用管道送往用戶,一種是在製氧車間以</span><span style="font-family:"Times New Roman";"><span lang="EN-US">15MPa</span></span><span style="font-family:宋體;mso-ascii-font-family:"mso-hansi-font-family:";">的高壓充瓶,將瓶裝氧氣運往用戶。不鏽鋼氧氣管道修理前應將修理斷與管網斷開,並用空氣、氮氣或蒸汽將氧氣全部趕走置換,不留死角。修理完後應按照要求進行強度和氣密性試驗。試驗合格後,正式送氧前應選用氧氣對管道進行吹洗,吹洗管道也可應用不含油的壓縮空氣或氮氣,氣流速度不小於</span><span style="font-family:"Times New Roman";"><span lang="EN-US">20m/s</span></span><span style="font-family:宋體;mso-ascii-font-family:"mso-hansi-font-family:";">,所有輸送氧氣的不鏽鋼管都應吹洗到。在氣流出口處用白紙檢驗,冇有塵粒和水分痕跡為合格。吹洗合格後再用容積不少於吹洗管的</span><span style="font-family:"Times New Roman";"><span lang="EN-US">3</span></span><span style="font-family:宋體;mso-ascii-font-family:"mso-hansi-font-family:";">倍氧氣換管內的吹洗氣體,且各個死角都應該設法置換到。置換管道的氧氣應排至室外,排除口離地麵不少於</span><span style="font-family:"Times New Roman";"><span lang="EN-US">2.5</span></span><span style="font-family:宋體;mso-ascii-font-family:"mso-hansi-font-family:";">米,並應遠離火源。輸送含濕氧的管道凍結時隻能用熱水或蒸汽融凍,嚴禁用明火融凍。</span></span> </p> <span style="font-family:宋體;font-size:small;"> </span> <p style="margin:0cm 0cm 0pt;"> <span style="font-size:small;"><span style="font-family:"Times New Roman";"><span lang="EN-US"> </span></span><span style="font-family:宋體;mso-ascii-font-family:"mso-hansi-font-family:";">廠區架空輸送氧氣不鏽鋼管支架,應采用非燃燒材料製作,在閥門、排水器及其他需要檢查維護的地方應安裝梯子和平台。含濕氧氣不鏽鋼管,在寒冷地區應采取防凍措施,防凍措施可采用敷設保溫層或加伴熱管。當采用伴熱管時,伴熱管的介質應采用不超過</span><span style="font-family:"Times New Roman";"><span lang="EN-US">90</span></span><span style="font-family:宋體;mso-bidi-font-family:宋體;">℃</span><span style="font-family:宋體;mso-ascii-font-family:"mso-hansi-font-family:";">熱水。</span></span> </p> <span style="font-family:宋體;font-size:small;"> </span> <p style="margin:0cm 0cm 0pt;"> <span lang="EN-US"><span style="font-family:"Times New Roman";font-size:small;"> </span></span> </p> <span style="font-family:宋體;font-size:small;"> </span>

為什麼醫院要采用不鏽鋼管輸送氧氣

  氧是自然界分布*廣泛的元素之一。它以遊離狀態和化合狀態存在於自然界中,空氣中遊離狀態的氧達20.93%。化合狀態的氧存在於水、礦物、植物和動物等物體中。在常溫及大氣壓力下,氧為無色、無味、無臭的透明氣體,比空氣略重。氧的化學性質非常活潑,是強烈的氧化劑和阻燃劑。在一般情況下,他除了與金、銀、鉑及惰性氣體不發生化合外,與其他物質都能化合生成氧化物,氧與其他物質化合的過程即為氧化反應。氧與可燃氣體如氫、乙炔、甲烷等按一定比例混合後很容易爆炸。氧經壓縮後在輸送過程中如有油脂、氧化鐵銷及其他易燃物質存在時,隨著氣流與管壁的摩擦撞擊產生大量摩擦熱,可能會導致不鏽鋼管和設備的介質燃燒或爆炸。壓縮氧氣混雜有水分,會使不鏽鋼氧氣管道產生凝結水,純度越高的氧氣對不鏽鋼管的腐蝕越嚴重。針對氧氣管道的這些特點,在管道安裝及維修中要合理選材,並有相應的技術措施。

  工業生產中使用的氧氣,一種是由製氧直接用管道送往用戶,一種是在製氧車間以15MPa的高壓充瓶,將瓶裝氧氣運往用戶。不鏽鋼氧氣管道修理前應將修理斷與管網斷開,並用空氣、氮氣或蒸汽將氧氣全部趕走置換,不留死角。修理完後應按照要求進行強度和氣密性試驗。試驗合格後,正式送氧前應選用氧氣對管道進行吹洗,吹洗管道也可應用不含油的壓縮空氣或氮氣,氣流速度不小於20m/s,所有輸送氧氣的不鏽鋼管都應吹洗到。在氣流出口處用白紙檢驗,冇有塵粒和水分痕跡為合格。吹洗合格後再用容積不少於吹洗管的3倍氧氣換管內的吹洗氣體,且各個死角都應該設法置換到。置換管道的氧氣應排至室外,排除口離地麵不少於2.5米,並應遠離火源。輸送含濕氧的管道凍結時隻能用熱水或蒸汽融凍,嚴禁用明火融凍。

 廠區架空輸送氧氣不鏽鋼管支架,應采用非燃燒材料製作,在閥門、排水器及其他需要檢查維護的地方應安裝梯子和平台。含濕氧氣不鏽鋼管,在寒冷地區應采取防凍措施,防凍措施可采用敷設保溫層或加伴熱管。當采用伴熱管時,伴熱管的介質應采用不超過90熱水。

 